The standby address in this example gets assigned to the secondary FWSM. • 6-slot chassis: slots 5 and 6 • 9-slot chassis: slots 5 and 6 • 13-slot chassis: slots 7 and 8The power supply you are calling "1800W" is really the WS-CAC-1300W supply, but it requires 1800W input because of the inefficiencies in AC->DC power conversion. Kind Regards, Wilson SamuelCisco Catalyst 6506-E, Catalyst 6509-E and Catalyst 6513-E Switches with Supervisor Cards (VS-S2T-10G and VS-S2T-10G-XL) and Line Cards (WS-X6908-10G and WS-X6908-10G-2TXL) FIPS 140-2 Level 2 Non-Proprietary Security Policy Overall Level 2 (Sections 3 and 10 Level 3) Validation Version 1. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all Cisco Catalyst 6500 E-Series Chassis. I have this problem too. Buy or Renew. 如果需要 思科 Catalyst 6513 交换机 文档的支持信息,则可通过 Cisco. 0. The document describes a procedure to use while the Supervisor Engine module is still up and running in the chassis, and a procedure to use when the Supervisor Engine module is removed from the chassis. I have an open slot and installed the new module there. Options. Catalyst 6513 chassis . Customers with active service contracts will continue to receive support from the CiscoIntroduction. My worry is that this site has power issues. Buy or Renew. 4 Clock A (CLK A) 2 VTT 2 . Cisco Catalyst 6500 Series Port Density Information, WAN Modules and Interfaces Maximum System Port. EN US. redundant routing and forwarding engines. c6svc-fwm-k9. What is the logical successor for them? 6800 series? Catalyst 6509-V-E Switch. The last day to order the affected product(s) is May 1, 2018. 2. ACL's on the MSFC should be applied to all inter-VLAN packets that flow through the 6513 regardless of any type of "bypass the MSFC" routing that is being done. Of course, all of this will need to be done in a maintenance window. As there's notIf you use the default configuration, native VLAN is set to VLAN 1. Initial Release. The steps for switch installation can be found here: Catalyst 3850 Switch Hardware Installation Guide. 77 You Save: $685. Responsibilities: Requirement Analysis, Solution Design, Deployment, UAT, Go LiveThe modules also work in Catalyst 6500 Series Switches. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. Cisco with the Catalyst 6500 is the best choice for architecting and deploying holistic, cost-effective network access architecture. ) Replacement Products of Cisco ISR 1900 Series: End-of-Sale Product Part Number. This document is Cisco Public Information. Cisco Catalyst 6807-XL Switch - End-of-Support Date: 30-Apr-2027. The CPU have been spiking multiple times every hour. The Cisco ® Catalyst ® 6500 Enhanced Series Chassis will be capable of delivering up to 180 Gbps of per-slot bandwidth with a system capacity of up to 4 terabits per second. EOS for Selective Cisco Catalyst 6503,Catalyst 6506 and Catalyst 6509 Chassis 08/Jan/2014. 8 26-Feb-2015. $87. Find quality network accessory products at discounted prices. I have connection between cisco 6513 core switch and 3560x. The Catalyst 6513 switch is a 13-slot (numbered from (1) top to (13) bottom), 20 RU, horizontal chassis that supports redundant power supplies and redundant supervisor engines. 3 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19058UN3. 00. I need to type this command at Global configuration mode. Le centre d’assistance technique de Cisco (TAC). Chinese; EN US; French; Japanese; Korean; PortugueseIt is running IOS, but when it reboots it goes straight into rommon. Find connection below. We reboot after changing the boot command and it seems as the upgrading process go through,. Subscribe to RSS Feed. . Or Visit our shop: Router-Switch. We have a wide selection of refurbished parts available for the Cisco 6513 Series Network Switch. End-of-Support Date: 2011-11-01 . It doesnt matter if i ping from my pc or from 6513. I am running image file: sup-bootdisk:s72033-ipservices_wan-vz. Solved: Hello Gents, Please let me know if we can configure VPC Between N5010 and 6513(coreswitch). Its hardware-based feature set enables applications such as traditional IP forwarding, Layer 2 and Layer 3 Multiprotocol Label Switching (MPLS) VPNs. However, these pair of switches have a large number of SVIs, have many. Router has many WAN links with MPLS and p2p connectivity. I have a Core 6513-E that reports high cpu consumptions. In addtion to Ankur's post if session 15 or 16 command doesnot work then you can use " Switch Console " command. Nov 17, 2022Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6513 Switch (Non-E chassis only). 0 (2)EX2 is connected to VSS on WS-X6904-40G linecards with a dual-home. Humidity. . 01-DEC-2014. WS-C6513-2500AC= Catalyst 6513 Chassis w/ 2500W AC Power Supply . . 5854 on port GigabitEthernet4/14. 07-21-2011 04:26 PM. In any case, the numbers would not be all zero if any flow control were occuring. As far as we know that we cannot run ISSU, thus we tried with an upgrade via changing the boot parameter. As soon as I type this command at Global configuration dhcp server start assigning IP. Additional Information . Once you move to the new hardware, you can change back. Campus LAN Switches - Compact. 05-14-2020 03:06 PM. Can occupy slots 1-6 and 9-13 in a Cisco Catalyst 6513-E. The last day to order the affected product(s) is August 4, 2012. It provides high density 1, 10, 25, 40, 50, 100, and 400 GE in a compact, 13-rack-unit modular chassis. The last day to order the affected product(s) is March 31, 2012. Based on Cisco UADP 3. You can add, replace, or remove modules without interrupting the system. Table 1 describes the end-of-life. Use the ACE module replacement procedure described in the User Guide for the Cisco Application Networking Manager 4. The ports on the exisiting module don't use all the same setti. The Cisco Catalyst 6500 Series provides the broadest selection of 10- and 100-Mbps media, densities, interoperability, and chassis deployment options (refer to Table 1). 2(1)SY7. Customers with active service contracts will continue to receive support from the Cisco Bias-Free Language. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all Cisco Catalyst 6500 E-Series Chassis. I am about to undertake a project to migrate our core switches to new hardware and am keen to find out the best way of doing this. Also just a quick check that the pc is not set up for static addressing. About. Cisco announces the end-of-sale and end-of life dates for the Select Cisco Catalyst 6503, 6506, and 6509 Chassis. The last day to order the affected product(s) is October 30, 2020. The software image upgrade is necessary when: 1. The 13-slot Cisco Catalyst 6513-E switch chassis is ideal for high-performance, high-port-density Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet aggregation throughout the network. Catalyst 6513 . The 13-slot Cisco Catalyst 6513-E Switch chassis is ideal for high-performance, high-port-density Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet aggregation throughout. Solved: I have a supervisor blade, (VS-S720-10G-3C), in a 6513 that is faulty and needs replaced. Options. The Catalyst 6500 can aggregate up to eight physical Fast Ethernet, Gigabit Ethernet or 10Gigabit Ethernet links into a single virtual link using Cisco’s Port Aggregation Protocol (PAgP) or IEEE 802. 4? IOS) version for a 6513 switch running supervisor 720, the aim of the upgrade is to support a WISM card that we are installing, since the current version doesn´t support it. 1 (2)SGx 04-Dec-2017. in my experience, means a power Field Replaceable Unit (FRU) has failed. Syslog message generated from device Chicago-6513: May 8 14:34:41 Chicago-6513. This provides network managers a reliable high-speed solution for the campus network backbone. com 18799: May 8 14:34:39. 06 You Save: $29. Refurbished units may be available in limited supply for sale inWS-C6513-E: Cisco Catalyst switch Enh C6513 Chassis, 13slot, 19RU, No Pow Supply, No Fan Tray, Desktop 20U, Modular Design, Hot Swap Modular Replacement, Cisco, Switch The 13-slot Cisco Catalyst 6513-E Switch provides high port densities that are ideal for many wiring closet, distribution, and core network as well as data center deployments. Status: End of Sale. The ports on the exisiting module don't use all the same setti. I need some assistance. Hello Jim, sh inventory. Step 5 Carefully press the module onto the connector. Is all the routing occurring on the 6513 and it is just the ALGO and voice VLAN? If so: ! conf t ! ip multicast-routing ! ip pim rp-address x. The 13-slot Cisco Catalyst 6513-E Switch chassis is ideal for high-performance, high-port-density Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet aggregation throughout the network, including: 13 slots, 19 RU. Cisco 7513 Router - Retirement Notification. Hi, We recently had a management card failure on a 6513 chasis. Console> (enable) set vlan vlan_list firewall-vlan mod_num. The last day to order the affected product (s) is. We have a Cisco 6513 Switch. . 1 project at East Zone Data Center. 30-port 100G/40G QSFP28 with 400G/200G/100G QSFP-DD fiber C9600X-LC-32CD. I have a cisco 6513 running CATOS but I would like to translate to Cisco IOS Software 12. Empty chassis weight: 102 lb (46. jp? Thanks. 08-02-2015 09:26 PM - edited 03-08-2019 01:13 AM. See below. Planned, designed and implemented Cisco VPN solution for. vlan access-map SECVLAN_MAP 20. 2(18)SXF . Router has many WAN links with MPLS and p2p connectivity. Cisco Catalyst 6513-E 交换机提供高端口密度,适用于多个配线间、分布和网络核心区域以及数据中心部署。 Cisco Catalyst 6500 E 系列机箱在同一机箱内可支持多代产品,降低了总拥有成本,从而提供优异的投资保护。Data Sheets. For a replacement, we recommend the Cisco Catalyst 6509-E Switch. Solution Support is the defaulted service. High-humidity conditions can cause moisture migration and penetration into the system. Series Release Date. (total 4x WS-CAC-3000W) Can we change WS-CAC-3000W to WS-CAC-6000W without downtime ? Can WS-CAC-3000W will work together with WS-CAC-6000W ? Thank you in advance. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6500 Switch Accessories. Log In. i have one ethernet modules installed . During some parts of the day it is having large amounts of transmit discards on a certain interface. EN US. It looks like the gigabit port was going up to 10MB which does not seem that high. Cisco Switch PN WS-C6513 Cisco introduces The Cisco Catalyst 6513 Enhanced Chassis is part of the Cisco Catalyst 6500 Series of enhanced (E-Series) switches, delivering up to 2 Terabits per second of system bandwidth capacity (80 Gbps/slot), and a rear serviceable fan tray for enhanced cable. Q1: When do logs. Reseating usually helps to recover this condition in case of transient failures but. The last day to order the affected product(s) is October 30, 2017. The noc will host some servers like nms, aaa, call manager, video streaming and antivirus stuff. Cisco Catalyst 9600 Series Line Cards Data Sheet. The forwarding engine on Supervisor Engine 2T is capable of delivering high-performance forwarding for Layer 2 and Layer 3 services. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Figure 1-9 Catalyst 6513 Switch Internal Airflow . Description of the problem given below: We are facing one major network issue for Ph-V. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. One of our Catalyst 6513 Access-Switches reboots every 2 or 3 days by itself. 122-33. Table 1. #show port-security interface. Replacing this supervisor and the chassis of the 6513Learn more about how Cisco is using Inclusive Language. Refer to this documentation for assistance on memory modules replacement: Memory Guidance for Cisco Catalyst 6500 Series. Buy Cisco Network Accessory WS-6513. It consists of 4 port groups of 4 ports each. Hello, We have 2x 6513 non E working in VSS mode. Depth: 18. Hi, We are trying to upgrade our 6807 VSS switches to 15. The Cisco ® Catalyst ® 6500/Cisco 7600 Series Supervisor Engine 720 is a family of Supervisor Engine (s) designed to deliver scalable performance and rich set of IP features in hardware. The Cisco Catalyst 6900 Series 8-Port 10 Gigabit Ethernet Fiber Module is only compatible with the new Cisco Catalyst 6500 Supervisor Engine 2T (VS-S2T-10G or VS-S2T-10G-XL), enabling the system to deliver three times the performance and four times the scalability for Cisco Catalyst 6500 Series Switches in comparison to the previous generation. I am capturing traffic with Netdr (), but the output has a few information. EOS for Selective Cisco Catalyst 6503,Catalyst 6506 and Catalyst 6509 Chassis 08/Jan/2014. 122-33. Login // Request A Quote. 4000 W Power Supply Specifications I will soon replace a Catalyst 6509 switch with a Catalyst 6513-E switch. Do the Express Setup to enter the initial IP information. g. Product Description. This moisture can cause corrosion of internal components and degradation of properties such as electrical resistance, thermal conductivity. Contact Cisco. The SFPs that used are XENPAK-10GB-LR forDisconnect all Ethernet cables from the switch. $4,658. Cisco FET-10G module The Cisco FET-10G Fabric Extender Transceiver supports link lengths up to 100m on laser-optimized OM3 or OM4 multimode fiber. End-of-Sale and End-of-Life Announcement for the Select Cisco Catalyst 6500 Line Cards, Power Supplies, and Accessories 02-Feb-2016. SXH5 s6523-mp001-pz. Your posting has helped. 0 ASIC, supports up to 2. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. AC power supplies, connectors, and cords for these switches are also covered. Hi , I have a device connected on the other side of the cisco 6513 , For example : --->6513-1(1/1) 6513-1 (2/2)--> PC . Show Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request). asdm-621f. WS-C6513-E-RF Cisco Catalyst 6513 Enhanced Chassis (Refurbished) Mfg Part No: WS-C6513-E-RF. Cisco TMP, customers should work with their Cisco Partner or Cisco account team. End-of-Sale Date: 2007-12-15 . The last day to order the affected product(s) is April 30, 2017. Need to know CISCO CATALYST 6513 13-SLOT CHASSIS BUNDLE EOL & EOSL Date? CISCO CATALYST 6513 13-SLOT CHASSIS BUNDLE EOL 07/31/2014 CISCO CATALYST 6513. 10/100/1000, 1G, 10G, 40G ports. The 6513 has been sitting in the office for a while and my boss would like to have it up and running so we can test blades; as in running traffic through the ports etc. We use Infoblox for DHCP. Cisco's End-of-Life Policy. Learn more. We reboot after changing the boot command and it seems as the upgrading process go through,. Here are the statistics before the ISSU process: The Catalyst 6500 chassis with Switch ID 1 is Active and the Switch with ID 2 is Standby (Hot). Copy the IOS into each individual supervisor card; 2. . You can view a listing. I am thinking I will need to create a trunk port from the Cisco 6513 to the SG300-10P, in order to carry my desktop data vlan. and what command need to enabled on switch 6513-2. Figure A-14 4000 W AC-Input Power Supply . Step 3. I was wondering what logic, if any, others use to place the modules in a chassis. Step 1 Remove the two screws that secure the VTT module. Cisco Internetwork Operating System Software . The following example shows output from the show memory debug leak command on command on a Cisco Catalyst 4500e switch, using a Cisco IOS image from Cisco IOS XE Release 3. 2-33. Layer 2 and Layer 3 connectivity between the two networks is required to allow successful applications and workload migration across the two network infrastructures. WS-C6513-2500AC= Catalyst 6513 Chassis w/ 2500W AC Power Supply . we bought 6513 in 2011 and till date we did face any problem. %OIR. - -. Both of the chassis are up on Cisco IOS Software Release 15. Figure 1-10 Catalyst 6513-E Switch Internal Airflow . Cisco Catalyst 6500, 6800 Series with. Strange, I think I'm ok for now, but definately will plan on upgrading those supplies (and my power outlets) to larger power supplies soon. I'm a recent Grad and just started to work for a cloud provider. Verify each IOS to make sure each file copied is not corrupt; 3. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 4948 Switch. Beginner Options. mydomain. Hello Guys, I have the following scenario: Two internet links from different SP using different routers an firewalls connected to a 6513. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6513 Switch (Non-E chassis only). Layering a comprehensive set of intelligent features onto a high-performance, protocol-independent switch fabric, the Cisco MDS. This versatile modular switch is designed for high-density, end-of-row, and high-performance aggregation-layer deployments in. Chinese; EN US; French; Japanese; Korean; Portuguese; Log InContact us now (cisco@router-switch. SXH3. The strange thing is that Cisco doesn't show the 1300 watt supply as supported in the 6513, but shows the 2500 watt supply in 1300 watt (110 Volt) mode as supported. 652). Also the power supplies leds indicate ok but no part number when I do a shpw power I get this: Router#sh power. Can any one tell me, what i have to d. com . The Cisco Catalyst 6500 Series Gigabit Ethernet modules support multiple queues per port for Quality of Service. The Gigabit Ethernet Copper. Cisco Catalyst 6513. 03-29-2010 10:20 AM - edited 03-06-2019 10:22 AM. I a. the backup card did not kick in, we had to reseat the primary card. Essentially each floor is its own vlan. However,we did a controlled test where we removed the primary card, the secondary kicked in fine. Replacing this supervisor and the chassis of the 6513 About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test. bin" · Problem Statement: System diagnostic reports on module number 12 show that the online tests for the system variable number “ 36, TestErrorCounterMonitor ” has failed the diagnostics tests five times. once you do that it. The Cisco Catalyst 6500-E Series Switch offers the broadest range of interface. 17d-SXB11 is working fine and I am able collect netflowThe card is failing loopback test. when I plug directly into the Cisco 6513 Core switch, the phone boots fine, gets its configuration and on the correct vlan 112. The WS-X6748-GE-TX Cisco Catalyst 6500 48 Ports Switch Module is a powerful and innovative device that provides additional connectivity options and features to Cisco Catalyst 6500 Series switches. 5 Clock B (CLK B) 3 VTT 3 : Replacing the VTT Module . On a Cisco Catalyst 6503-E and 6504-E module current is @50V; On. Bias-Free Language. Router#sh version . High-density fiber line cards for campus core. Weight. Buy Cisco Network Accessory WS-C6513-RACK-RF. com computer parts component whoelsale store. 0 (2)EX2 is connected to VSS on WS-X6904-40G linecards with a. Replacement Product Part Number . D Catalyst 6006, 6009, 6506, 6509 . Replacement Product Description Additional Information WS-C6513 Catalyst 6500 13-slot chassis, 20RU, no PS, no Fan Tray. Cisco 550X Series Stackable Managed Switches Overview. The last day to order the affected product (s) is October 30, 2020. Cisco announces the end-of-sale and end-of-life dates for the Cisco Industrial Ethernet 3000 Series Switches. Status: End of Sale | End-of-Support Date: 31-Oct-2025. [email protected] (31)SGA 15-Oct-2013. SE5. 30-port 100G/40G (QSFP28) and 2-port 400G/200G/100G. Cisco's End-of-Life Policy. Preface; Chapter 1 --- Product Overview;. Cisco TAC will immediately replace your blade (if, of course, you have a valid service contract). 53 $6,211. 5(1) sy4, we run now on version 15. A single 6800IA that runs Cisco IOS software Release 15. IT Hardware Maintenance. The 16-port 10 Gigabit Ethernet fiber module (Figure 2) provides up to 130 10 Gigabit Ethernet ports in a single Cisco Catalyst 6509 chassis and 260 10 Gigabit Ethernet ports in a VSS and is designed for LAN campus aggregation and data center access, where fanout and port density are very important. Can I run GLBP. Page 1 of 4 Cisco Catalyst 6513-E Chassis Product. Catalyst 6500 13-slot chassis, 20RU, no PS, no Fan Tray - WS-C6513-2500AC= Catalyst 6513 Chassis w/ 2500W AC Power Supply . Buy or Renew. Learn more about how Cisco is using Inclusive Language. If the switch is running native IOS then you are in the RP and to manage the switch all you have to do is this. Documentation. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL,. The last day to order the affected product(s) is June 30, 2020 . 1. $2,057. Cisco Catalyst 6513 Enhanced Chassis Spare WS-C6513-E= Cisco Catalyst 6513 Enhanced Chassis Fan Tray Spare WS-C6513-E-FAN= Cisco Catalyst 6500 1400 W AC Power Supply PWR-1400-AC= Cisco Catalyst 6500 2700W AC Power Supply PWR-2700-AC/4= Cisco Catalyst 6500 3000W AC Power Supply WS-CAC-3000W=The 6000-watt (W) power supply for the Cisco ® Catalyst ® 6500 Series chassis (Figure 1) is a dual AC input power supply. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories. The Cisco Catalyst 4500 Series is a mid-range modular chassis network switch. 1". Yes i do see that the Cisco 6513 has a voice vlan configured with an ip helper, when i run the command provided i do see some assigned addresses but none match the addresses assigned to the phones. In the event of failover, the users will still be able to to get to the primary (re: non-standby) address. Help you find the best switch for your needs. EOS & EOL: Select Cisco Catalyst 6500 Series Components-Updated 03/Aug/2005. SXF8. With the 3000 series, look for the 9300 catalyst switches for your layer 3 work horse. WS-C6500-SFM2 is inserted into slot 7 or slot 8 on a 6513 Chasis. Ensure the config-registry value is 0x2102; 5. Page 1 of 4 Cisco Catalyst 6513-E Chassis Product. Labels: Labels:Options. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table. The last day to order the Cisco Catalyst 6500 Series Supervisor Engine 2 Related Memory Modules is. Expansion / Connectivity Expansion Slots 13 (total) / 13 (free) x expansion slot Installed Modules Qty. CHAPTER 1-1 Cisco IOS Software Configuration Guide, Release 15. com 18799: May 8 14:34:39. match ip address SECVLAN. {Switch Replacement for J9772A} $1,495. I haven't removed the old module as 36 ports are still in use. I'm guessing I need the one that starts. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. The Cisco TelePresence TX1300 Series has been retired and is no longer supported. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories 06/Jan/2015. 2(2)T1. Cisco Catalyst 6900 Series 4-port 40 Gigabit Ethernet Fiber Module can operate in a number of modes. 00. Hello, We have 2x 6513 non E working in VSS mode. CBS350-48FP-4G. Hi Experts We are having two cisco 6513 switches with SUP 720. Supported on Cisco Catalyst 6503-E, 6504-E, 6506-E, 6509-E, 6509-V-E, 6513-E. com. 2 (1)E 10-May-2015. SXH 5 What is the difference between these images. Need to upgrade to add additional support for WS-X6708-10G-3C (10Gb line cards) The card requires 12. Find quality network accessory products at discounted prices. The 13-slot Catalyst 6513 chassis is ideally suited for high performance, high port density Fast Ethernet and Gigabit Ethernet aggregation in all parts of the network including the access, distribution, and. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 2960-CX Series Switches. ISR4221/K9. 128 KB. We have Avaya VoIP phones on the network and they work fine, the. Cisco Partners can findCisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6513 Switch (Non-E chassis only). But as per you WS-X6748-GE-TX is a dual-channel line card which can only be installed on slots 9-13. 60950, CISPR 22 Class A, EN 60950, EN 61000-6-1, UL 1950, VCCI Class A ITE, AS/NZS 60950-1, AS/NZ 3548 Class A, EN55024, EN55022 Class A and EN50082-1. , SUP version, CatOS/IOS version) and perhaps post some configs along with examples of traffic that. I will be placing this in multiple vlans along with noc users. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. A, B and C. In. This appears to me as incomplete information since the C881-K9 is without the AdvIPservices license. ON the 6513 I have applied the followingSo it's a multicast issue then. Site A, contains two Cisco 4506 switches that are end of life and are the ones scheduled for replacement. Cisco Catalyst 6500 Series VPN Services Port Adapter 24/Oct/2016. WS-C6513-E - Cisco 13-Slot Chassis for Catalyst Enhanced C6513. Cisco 6513 Span session Limit fhoban. Find quality network accessory products at discounted prices. Table 1 describes the end-of-life milestones, definitions, and dates for. 2 (31)SGA 15-Oct-2013. Call Sales: 1-800-553-6387 5am. According to the Vmware engineer it should be set to auto for the VLAN tagging. Weight. WS-C6513-E-RF Enh C6513. This document explains the step-by-step procedure to upgrade the software image on Catalyst 6000/6500 series switches that run Catalyst Operating System (CatOS) on Supervisor, Cisco IOS® on MSM/MSFC and Cisco IOS System Software. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Any other preparation recommendations? Thanks for your time.